DeviceMaster UP Modbus/TCP Quick Start: 2000477 Rev. G Configuring Read/Write Raw/ASCII Devices - 47
Configuring Read/Write Raw/ASCII Devices
Transmit messages have the following characteristics:
• All data is transferred in 16 bit words.
• If operating in Tx (From PLC) Transfer Mode of Master (Poll the PLC): The sequence number must be
incremented when there is new data to transmit.
• If operating in Tx (From PLC) Transfer Mode of Slave (PLC Writes): The sequence number must be
incremented when there is new data to transmit only if the Disable Tx Sequence Number Check is not
selected.
• The data length field indicates the number of valid bytes contained in this message.
• The actual length of the message received from a PLC may contain extra, unused data.
• Unused data is ignored.
• A request for transmit data returns the last transmit data message.
Read/Write Raw/ASCII Ethernet Devices
Read/write raw/ASCII
Ethernet devices use the
Ethernet Device
Configuration page to:
• Allow connections
between an Ethernet
device, such as a
barcode scanner, RFID
reader, or weigh scale,
and a PLC and/or an
application.
• Raw/ASCII data is the
only supported data
type.
• The Ethernet device
must support Ethernet
TCP socket
connections.
Note: The PLC and
applications can
both communicate to the Ethernet device, but they cannot communicate directly to each other.